The Marco Beverage Systems MIX UC3 and UC8 water boilers use a thermistor to read the temperature inside of the boiler.
To test a thermistor to confirm it is working within range, please see the chart below.
| Temperature (C) | Resistance (K-Ohms) |
| 20 | 22 |
| 70 | 11.67 |
| 71 | 11.46 |
| 72 | 11.25 |
| 73 | 11.04 |
| 74 | 10.83 |
| 75 | 10.62 |
| 76 | 10.41 |
| 77 | 10.20 |
| 78 | 9.99 |
| 79 | 9.78 |
| 80 | 9.57 |
| 81 | 9.36 |
| 82 | 9.15 |
| 83 | 8.94 |
| 84 | 8.73 |
| 85 | 8.52 |
| 86 | 8.31 |
| 87 | 8.10 |
| 88 | 7.89 |
| 89 | 7.71 |
| 90 | 7.53 |
| 91 | 7.30 |
| 92 | 7.00 |
| 93 | 6.81 |
| 94 | 6.62 |
| 95 | 6.36 |
| 96 | 6.19 |
| 97 | 6.01 |
| 98 | 5.82 |
| 99 | 5.60 |
| 100 | 5.42 |
Please note there is a tolerance of +/- 2%